TOA FV-200CA Amplifier Changeover Panel

Product Overview

The FV-200CA Amplifier Changeover Panel is used to automatically changeover FV-200 Series fault duty amplifier to working standby amplifier. 1 unit of FV-200CA can handle up to 6 nos. of FV-200 Series amplifiers.

Specifications

Power Source
24 V DC (operating range: 21.6 - 26.4 V), M3 screw terminal
Current Consumption on 24 V DC Power Input
240 mA
Number of Input Channel
6 Duty Amplifier, 1 Standby Amplifier
Number of Output Channel
6 Output
Failure Detection
Fault Buzzer with buzzer control switch
LED Indicator
Power (Green), Changover (Orange), Fault / Buzzer Control (Red)
Operating Temperature
0 °C to +40 °C
Operating Humidity
Under 90% RH (no condensation)
Finish
Front Panel : Aluminum, black, alumite
Dimensions
482 (W) × 44 (H) × 343.8 (D) mm
Weight
2.6 kg
Included Accessories
Removable terminal plug (2 pins) x 3, removable terminal plug (8 pins) x 4